Material guide for filter support mesh
Choose the material for the fluid, the temperature and the cleaning regime; then choose the construction for the load. Ratings are for general guidance at moderate concentration and temperature.
Stainless steels and nickel alloys
| Material (EN / UNS) | Max. service in air* | Oxidizing acids | Reducing acids | Alkalis | Chlorides | Tensile Rm MPa** | Typical use |
|---|---|---|---|---|---|---|---|
| 304 (1.4301 / S30400) | 925 °C | Good | Limited | Very good | Limited | ≥ 515 | General liquid filters, washable filters, food |
| 316L (1.4404 / S31603) | 925 °C | Good | Moderate | Very good | Moderate | ≥ 485 | Chlorides, marine air, chemical and hygienic service |
| 310S (1.4845 / S31008) | 1,150 °C | Good | Limited | Very good | Limited | ≥ 515 | Hot gas, furnace and kiln filtration |
| Inconel® 600 (2.4816 / N06600) | 1,175 °C | Moderate | Moderate | Excellent | Good | ≥ 550 | Hot caustic, high-temperature oxidizing gas |
| Inconel® 625 (2.4856 / N06625) | 980 °C | Very good | Very good | Very good | Excellent | ≥ 827 | Seawater, sour and chloride service |
| Hastelloy® C-276 (2.4819 / N10276) | 1,040 °C | Very good | Excellent | Very good | Excellent | ≥ 690 | Strong reducing acids, wet chlorine, mixed chemicals |
| Titanium Gr 2 (3.7035 / R50400) | 425 °C | Excellent | Poor | Good | Excellent | ≥ 345 | Seawater, chlorides, oxidizing acids |
Coated steels, aluminium and polymers
| Material | Max. service* | Service notes | Used in |
|---|---|---|---|
| Low-carbon steel + epoxy | About 120 °C (coating) | Mineral oils, lube oils, diesel; not phosphate-ester fluids | Epoxy coated screen |
| Galvanized steel (strip to EN 10346) | About 200 °C (zinc) | Indoor and outdoor air, humid intake air; poor in acids and alkalis | Expanded metal, welded mesh |
| Aluminium 5154A / 5056A | About 120 °C (epoxy) | Lightweight engine and HVAC filters | Epoxy coated screen, expanded metal |
| Polyester (PET) | 150 °C | Good in acids, limited in alkalis | Membrane support mesh |
| Nylon (PA6 / PA66) | 100-115 °C | Good in alkalis, limited in acids | Membrane support mesh |
| Polypropylene (PP) | See product page | Humid, acidic or incinerable filters | PP support mesh |
* Typical maximum continuous service temperature in clean, dry air for the metal or, where stated, for its coating. Actual limits depend on load, atmosphere and duty cycle. Aluminium-magnesium alloys with more than 3 % Mg are not recommended for sustained service above about 65 °C in corrosive environments. ** Minimum tensile strength, annealed condition, as specified in ASTM A580 (stainless wire), ASTM B166, B446 and B574 (nickel alloys) and ASTM B348 (titanium); galvanized strip to EN 10346 DX51D: 270-500 MPa. The actual value of each heat is stated on the EN 10204 3.1 mill certificate. Inconel® is a trademark of Special Metals Corporation; Hastelloy® is a trademark of Haynes International.
Quick selection
Hydraulic fluids
Mineral oils: epoxy coated steel screen. Phosphate-ester fluids: stainless 316L woven mesh.
Humid or coastal air
Welded mesh hot-dip galvanized after welding (GAW), or stainless 316L for the longest life.
Above 450 °C
310S or nickel alloys. Above 925 °C, nickel alloys only.
Food and pharma
316L woven cloth; PET or PA6 monofilament with FDA test reports.
Full data in the catalogue. Specifications, tolerances, materials and inspection for all six support media are in the MAISHI Filter Support Mesh Catalogue (PDF, 32 pages, 1.7 MB).
Not sure which material fits your service?
Send the fluid, temperature, pressure and cleaning regime. We recommend a material and construction.
Frequently asked questions
Which support mesh material for phosphate-ester hydraulic fluid?
Stainless steel 316L. Epoxy coated screen has good resistance to mineral hydraulic oils, lube oils and diesel but is not recommended for phosphate-ester fluids.
What is the maximum temperature for galvanized and epoxy coated support mesh?
About 200 °C for zinc coatings and about 120 °C for continuous service of epoxy coated mesh. Above 450 °C use 310S or nickel alloys; above 925 °C, nickel alloys only.
Where do the tensile strength values come from?
They are minimum tensile strengths in the annealed condition as specified in the ASTM product standards (stainless wire ASTM A580; nickel alloys ASTM B166, B446 and B574; titanium ASTM B348) and EN 10346 for DX51D galvanized strip. The actual value of each heat is stated on the EN 10204 3.1 mill certificate.